Testomat 2000® Br2

Product number: 100520
6.837,50 €*
* Prices excl. VAT plus shipping costs.
Heyl

Available variants

Language in the display: English, French, German
Performance/execution: 115 V/50-60 HZ, 230 V/50-60 HZ, 24 V/50-60 HZ

Product information

Dimensions: 380 x 280 x 480 mm
Weight: 10,600 kg
Measurement parameters: Bromine Br2
Measuring range: 0.00 – 5.60 mg/l Resolution: 0.02 mg/l (ppm) in the range 0 – 2.23 mg/l (ppm) Resolution: 0.2 mg/l (ppm) in the range 2.3 – 5.6 mg/l (ppm)
Range of application: Monitoring of disinfectant dosing
Menu navigation: German, English, French

Description

Description "Testomat 2000® Br2"

Online Bromine Analyzer for Process Monitoring

Continuous Br2 analysis with automatic reagent dosing and limit monitoring

The Testomat 2000 Br2 is an online analysis device for continuous monitoring of bromine (Br2) levels. After a short reaction time of approximately one minute, it delivers precise results in the range of 0–5.6 mg/L (ppm). The device features two independently programmable limit contacts for monitoring and controlling external processes. Analyses can be triggered automatically at intervals or via external signals, while internal error documentation and a programmable maintenance interval ensure reliability.

The Testomat 2000 Br2 is suitable for monitoring disinfectant dosing and quality assurance of water in technical systems. After automatic addition of reagents, the measurement result is displayed on a plain-text screen, and two limit contacts can be used for switching or alarm functions. External controls or water meter signals can influence the analysis triggering.

Functions of the Testomat

Two independently programmable limit contacts allow monitoring of critical bromine concentrations and integration into automated control processes. Additionally, the device can monitor two measurement points using external solenoid valves.

Typical Applications

  • Swimming pools and indoor pools
  • Process water in industry
  • Water treatment plants
  • Food and beverage industry

Why is bromine measurement important?

Bromine is used as a disinfectant and is only effective within a narrow concentration range. Too low bromine levels lead to insufficient disinfection, while too high levels can cause material damage, irritation, and unnecessary chemical consumption. Continuous bromine monitoring ensures safe dosing, protects equipment, and guarantees consistent water quality in swimming pools, process water, and industrial water applications.

Performance Profile of the Testomat 2000 Br2

  • Analysis via automatic dosing of 2 reagents
  • Measurement result display after approx. 1 minute reaction time
  • 2 independently programmable limit contacts for monitoring and control tasks
  • Menu-guided operation and programming via plain-text display
  • High measurement accuracy thanks to precise piston dosing pump
  • Analysis triggering:
    • Automatic interval mode (interval pause adjustable from 0–99 minutes)
    • External triggering
    • Quantity-dependent via contact water meter
  • Two independent limits with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions
  • Monitoring of two measurement points (switching via external solenoid valves)
  • Internal error documentation
  • Programmable service address
  • Programmable maintenance interval for maintenance requests

Shop