Water treatment system for outpatient clinics; incl. lifting system, UV system, pyrogen filter, Aqua-Stop, collection trays, viewing window and NeoTecMaster

Product number: 896526
31.297,90 €*
* Prices excl. VAT plus shipping costs.
Heyl Neomeris

Description

Description "Water treatment system for outpatient clinics; incl. lifting system, UV system, pyrogen filter, Aqua-Stop, collection trays, viewing window and NeoTecMaster"

Note: The system shown, consisting of two cabinets, is the fully equipped version of our system. The basic price is therefore supplemented by the selected options.

The modular water treatment system was specially developed for the outpatient care sector. While the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the the quantities required in different outpatient centers, as well as to the initial water quality, including any treatment treatment steps on the part of the supplier. The modularity offers the decisive advantage that the overall concept can be adapted to the respective water type or composition as well as the supplier's treatment processes.

Principle
Due to its modular design, the water treatment system can be adapted to the different conditions in outpatient care. to the different conditions in the outpatient care sector. be adapted. These include different degrees of water hardness, quantities required in outpatient centers, the initial water quality and the treatment steps. Optimum water treatment is relevant for the reliable availability of instruments for for operations. It also goes hand in hand with the protection of and equipment technology. Furthermore, any damage to the damage to the instruments or equipment is always directly directly related to the issue of patient safety. For the pre-filtration, a softening system and a reverse osmosis system with a 100 liter permeate a reverse osmosis system with a 100 liter permeate tank including surge tank and sterile filter as well as permanent conductivity and silicate silicate monitoring using a Testomat® 808 SiO2 on the blending bed and recirculation system with integrated UV system and pyrogen filter

Wastewater discharge via brine lifting unit
As an optional component, the treatment plant can be extended by an integrated wastewater lifting unit. integrated wastewater lifting unit, which discharges the generated and and collected wastewater into the sewer system. The main wastewater volume flows are the wastewater from the regeneration of the of the softening plant and the concentrate from the reverse osmosis should be mentioned. The discontinuously occurring wastewater flows from the wastewater flows from the silicate meter, the system separator and the rinsing water that is produced when the input filters (in particular

Cut-off via system separator
To protect the drinking water network from contamination by treated water or changes in the natural composition of the water, the system separator is also used. water or changes in the natural composition of the of the drinking water fed into the system due to the technical treatment the installation of a system separator is mandatory. The system has an integrated system separator (type BA), which is located directly behind the Aqua-Stop of the water connection.

Rittal enclosure systems
The system components are installed in two Rittal enclosures. Rittal is a leading manufacturer of enclosure systems and offers a wide range of range of solutions for the secure storage and protection of electronic electronic components and devices. Rittal enclosure systems are available in various sizes, designs and configurations and configurations and are suitable for various application areas such as IT infrastructure industrial automation, power distribution and telecommunications.
Rittal enclosure systems are characterized by high quality, functionality and flexibility. and flexibility. Rittal enclosures are made from high-quality materials and offer a robust construction that provides reliable protection reliable protection for the equipment inside. They are protected against dust, dirt, moisture, vibrations and other environmental environmental influences. Rittal enclosure systems are modular which means that they can be adapted to the specific requirements and the available space. They offer a variety of options for mounting accessories such as shelves, cable management, climate control units and power distribution units. The enclosure systems from Rittal offer various security features such as lockable doors, security locks and access control systems, to prevent unauthorized access to the equipment and ensure data security. data security. For the installation of the modular water treatment plant from HeylNeomeris only requires a minimum footprint of footprint of 1.60m x 1m is required. It consists of 2 cabinets that are 80cm wide and 60cm deep. It is possible to work with double-wing doors and thus, due to the depth of 60cm and a double of 60cm and a double wing door with a dimension of 40cm, this results in a
The cabinets used are made from sturdy sheet steel modules and have a high-quality surface coating. and have a high-quality surface coating.

Standard equipment of the system

Testomat® 808 SiO2 silicate measuring device
A Testomat® 808 SiO2 silicate measuring device is used for continuous silicate monitoring. SiO2 silicate is used. The Testomat®808 SiO2 is a measuring device, which is used to determine the silicate content in water. The measuring principle of the Testomat®808 SiO2 is based on the so-called molybdenum blue method. The silicate in the water reacts with a reagent solution containing molybdenum. This reaction produces a blue color whose intensity is proportional to the silicate content. The measuring device records the color intensity using an optical sensor and converts it into a measured value that represents the silicate content of the water. of the water. The Testomat®808 SiO2 is housed in a compact casing which contains a user interface, display and control elements as well as and connections for water samples and drainage.
The use of Testomat 808®SiO2 ensures reliable compliance with the requirements of the DGSV and AKSV. compliance with the limit value for SiO2 recommended by the DGSV and AKI of of 0.4 mg/l is ensured.
If the limit value is exceeded, it is possible to report this to the optionally available to the optionally available NeoTecMaster® or directly to an optical warning directly to an optical warning element. Continuous monitoring of the silicate content is required, deposits and any resulting damage to equipment and instruments. damage to device technology and instruments effectively.
By using the Testomat®808 SiO2, companies can continuously monitor the silicate silicate content and, if necessary, take appropriate measures to prevent deposits.

UV Disinfection Mini
UV disinfection is used in water treatment to remove any microorganisms from the water. water from any microorganisms such as bacteria, viruses and protozoa. protozoa. UV stands for ultraviolet radiation, which is generated by generated by special UV lamps. The principle of UV disinfection is based on the inactivation of the microorganisms' DNA or RNA, preventing them from multiplying and causing disease. cause disease. UV disinfection is relevant because UV radiation is effective against a wide range of microorganisms, including bacteria, viruses and protozoa such as Giardia and Cryptosporidium. A high inactivation rate can be achieved and most pathogenic organisms in the water can be pathogenic organisms in the water can be killed. In contrast to other disinfection methods such as chlorination or ozonation, UV disinfection UV disinfection does not require the addition of chemicals to the water. It does not produce any unwanted by-products and does not change the the taste or smell of the water. UV disinfection is a reliable method of killing microorganisms. As long as the UV lamp is properly maintained, the effectiveness of disinfection remains constant. remains constant. As no chemicals are used in UV disinfection, there are no harmful chemicals, there are no harmful residues in the water or the environment. environment. It is an environmentally friendly disinfection method that reduces the ecological footprint of water treatment. It is important to note that UV disinfection is an effective method for killing microorganisms microorganisms, but not for removing pollutants, particles or chemical impurities in the water.

Pyrogen filter
A pyrogen filter is a special type of filter used in water treatment to remove pyrogens from water. to remove pyrogens from the water. Pyrogens are substances that can cause an immunological reaction in the body in the body, in particular an increase in body temperature. As a rule These are usually endotoxins, which are produced by bacteria such as Escherichia coli (E. coli), for example. The pyrogen filter consists of a filter element that has a very fine pore size typically in the range of 0.1 to 0.2 micrometers. This enables the filter to effectively retain particles and microorganisms, including pyrogenic bacteria that may be present in the water. may be present in the water. In the modular water treatment system the pyrogen filter is used after other pre-treatment stages such as filtration and disinfection. After the water has been cleaned of particles and microorganisms particles and microorganisms, it is passed through the pyrogen filter to remove remove possible pyrogens. Pyrogen filters are particularly important in industries in which the absence of pyrogens in the water is of crucial importance, for example in the ambulatory care sector, in order to ensure the optimum quality of instruments for operations. Overall, pyrogen filters play an important role in water treatment, to ensure the quality and purity of the water and minimize potential exposure to pyrogenic substances.

Lifting system
The lifting system is used to reliably remove the wastewater volumes generated from the individual process steps. from the individual process steps. The main volume flows here are the waste water from the regeneration of the softening system and the concentrate from reverse osmosis. The discontinuous wastewater flows from the silicate meter are also collected in the lifting unit. wastewater flows from the silicate meter, the system separator and the rinse water rinsing water, which is produced when the input filters (in particular activated carbon filters)

NeoTecMaster® 5 inch with housing
Data acquisition and its visualization and processing are just some of the relevant topics in the environment of a modern some of the relevant topics in the field of modern water treatment. The networking of different measuring systems and their integration into process automation is an elementary component here. The NeoTecMaster® was specially developed for this task and is a manufacturer-independent multi-parameter system.

The data recording and visualization of the NeoTecMaster®
The visualization of the multicontroller takes place via trend graphs. All configured parameters can be selected and deselected. All recorded data is saved on a USB stick and is also available online can also be accessed online within the company network. You can monitor and visualize up to 8 parameters via the toggle button.
The NeoTecMaster is available with a 5 -inch screen and additional IP 66 housing.
The NeoTecMaster® Multicontroller concept is a basic building block for every water treatment plant, including water treatment system, even for systems in outpatient clinics.

Viewing window
Viewing windows are installed in the Rittal enclosures, which provide an overview of the measurement technology. of the measurement technology. The use of viewing windows in Rittal enclosure systems has several advantages. They enable a visual inspection of the of the devices in the enclosure without having to open the enclosure. having to be opened. This facilitates the monitoring, maintenance and troubleshooting of components without compromising the integrity of the is compromised. The viewing windows are usually made of a transparent transparent material such as glass.
Notes: Viewing windows in the Rittal enclosures are only available for single-leaf doors. When selecting this option, please ensure that the required minimum room depth increases from increases from 100 cm to 140 cm.


Aqua-Stop (solenoid valve shut-off)
An Aqua-Stop is a safety mechanism used in water supply systems to stop the flow of water. used in water supply systems to stop or limit the flow of water limit the flow of water if a malfunction or leak occurs. It is It is usually an automatic closing mechanism that closes the water water supply valve to prevent major water damage.
A solenoid valve is a type of shut-off valve that is controlled by the use of an electromagnetic field. controlled by the use of an electromagnetic field. In water treatment a solenoid valve is used to shut off or regulate the flow of water. used. The solenoid valve consists of an electromagnetic coil system and a valve mechanism. By applying an voltage to the coil generates a magnetic field that influences the valve mechanism. influences the valve mechanism. Depending on the application, the solenoid valve can opened or closed to allow or block the flow of water. or block it. In combination, additional safety and control over the control over the water flow can be guaranteed.
The Aqua-Stop is located directly behind the main water connection of the system as the first element. water connection of the system. The associated solenoid valve is coupled with two sensors, one of which continuously monitors the base trays of each of the two cabinet systems is continuously monitored.

Collection tray

Optional components of the system:
  • Lighting