Product information

Dimensions: 380 x 280 x 480 mm
Weight: 10,600 kg
Measurement parameters: Chromate | Chrome-VI
Measuring range: Chromate 0-2.0 mg/l (0.00-0.99 mg/l, resolution 0.01 / 1.0-2.0 mg/l, resolution 0.1) | Chromium-VI 0-1.0 mg/l (resolution 0.01)
Range of application: Monitoring of process and waste water in the galvanic industry | Control of process water flows in the metalworking industry
Menu navigation: German, English, French

Description

Description "Testomat 2000® CrVI (Standard)"

Testomat 2000 CrVI (Standard) – Reliable Monitoring of Chromate and CrVI

Reliable control of Chromate and Chromium VI in process water with the T 2000 from Heyl

The Testomat 2000 CrVI (Standard) is an online analysis device for monitoring Chromate (CrO42-) concentrations from 0 to 2.0 mg/l or Chromium VI (CrVI) concentrations from 0 to 1.0 mg/l. It uses a photometric analysis method with automatic reagent addition and delivers results after a short reaction time directly for process control.

The device operates with a photometric measurement principle, where two reagents are automatically dosed. After approximately two minutes of reaction time, the measurement results are available. Two independently programmable limit contacts allow direct integration into monitoring or control systems.

Technical Features of the Testomat 2000 CrVI

The photometric measurement principle combined with automated reagent addition distinguishes the Testomat 2000 CrVI. This allows reliable measurement of Chromate and CrVI. Measurement data can also be logged via optional interfaces. The clear-text menu simplifies configuration and operation.

Typical Applications of the T 2000 CrVI

  • Monitoring chromate content in wastewater from electroplating facilities
  • Control of wastewater in the metalworking industry

Why is Monitoring Chromate and Chromium VI Important?

Chromium VI is highly toxic and subject to strict legal limits. Continuous monitoring of Chromate and CrVI allows early detection of limit exceedances, protects humans and the environment, and ensures compliance with environmental regulations in process and wastewater systems.

Performance Profile of the Testomat 2000 CrVI

  • Analysis via automatic dosing of 2 reagents
  • Measurement result displayed after approx. 2 minutes of reaction time (excluding flushing time)
  • 2 independently programmable limit contacts for monitoring and control tasks
  • Menu-guided operation and programming via clear-text display
  • High measurement accuracy through precise piston dosing pump
  • Analysis triggering:
    • Automatic interval operation (interval pause adjustable from 0–99 minutes)
    • External control
    • Dynamic (exhaustion-dependent interval operation)
    • Volume-dependent via contact water meter
  • Two independent limit values with hysteresis (1, 2, or 3 faulty analyses) and adjustable switching functions
  • Monitoring of two measurement points (switching via external solenoid valves)
  • Internal error documentation
  • Programmable service address
  • Programmable maintenance interval for maintenance request